First page Back Continue Last page Graphics
CONCLUSIONS
The steel structural members penetrating the exterior enclosure exhibited significant thermal bridging as evidenced by the temperature gradients along their lengths (and between interior and exterior surfaces).
The mullion/glazing exhibited a more abrupt temperature change between inside and outside (at junction between the two), indicating less thermal bridging than the structure.
The steel stud/metal cladding system exhibited less thermal bridging than the structural members.